J355 M30-P1 Range is recommended for vehicular access control and perimeter protection in critical areas. Able to arrest a 6.800kg truck driving at 50km/h in single unit installation.
- Certified according to ASTM F 2656-07 Standards
- Impact resistance class M30 IN SINGLE CONFIGURATION
- Able to stop a 6,800 kg lorry travelling at 50Km/h (=30M/h) with just 1 metre of total penetration (P1)
- Lock in raised position guaranteed even in the event of a power cut
- Also available in the EFO (Emergency Fast Operation) version for very fast rise
- Integrated hydraulic unit
Technical Specifications
| J Series Model | J355 M30-‐P1 HA
H1.000 |
J355 M30-‐P1 HA
H1.000 INOX |
J355 M30-‐P1 HA EFO
H1.000 |
J355 M30-‐P1 HA EFO
H1.000 INOX |
| Drive | Hydraulic unit | Hydraulic unit | Hydraulic unit | Hydraulic unit |
| Cylinder height from ground [mm] | 1.000 | 1.000 | 1.000 | 1.000 |
| Cylinder diameter [mm] | 355 | 355 | 355 | 355 |
| Cylinder material
|
Steel S355JR EN
10210 (16mm thick) |
Steel S355JR EN
10210 (16mm thick) |
Steel S355JR EN
10210 (16mm thick) |
Steel S355JR EN
10210 (16mm thick) |
| Cylinder surface | Cataphoresis and
polyester powder painted Dark grey metallized RAL 7021 |
Satin finishing | Cataphoresis and
polyester powder painted Dark grey metallized RAL 7021 |
Satin finishing |
| Head
|
Aluminium painted
case RAL 9006 |
Aluminium painted
case RAL 9006 |
Aluminium painted
case RAL 9006 |
Aluminium painted
case RAL 9006 |
| Rising time [s] | ~6 | ~6 | ~6 | ~6 |
| Emergency fast rising | NO | NO | YES (E.F.O) | YES (E.F.O) |
| Emergency fast rising time [s] | -‐ | -‐ | ~1,5 | ~1,5 |
| Lowering time [s] | ~2 | ~2 | ~2 | ~2 |
| Emergency manual lowering | YES (Option) | YES (Option) | YES (Option) | YES (Option) |
| Power supply | 230V ~ 50(60Hz) | 230V ~ 50(60Hz) | 230V ~ 50(60Hz) | 230V ~ 50(60Hz) |
| Max power consumption [W] | 2.500 | 2.500 | 2.500 | 2.500 |
| Max pushing force [N] | 5.000 | 5.000 | 5.000 | 5.000 |
| Hydraulic unit protection Index | IP67 | IP67 | IP67 | IP67 |
| Suggested Usage | Perimeter protection | Perimeter protection | Perimeter protection | Perimeter protection |
| Reflective strip height [mm] | 55 | 55 | 55 | 55 |
| Reflective strip colour | White | White | White | White |
| Impact resistance [J] | 150.000 | 150.000 | 150.000 | 150.000 |
| Break in resistance [J] | 656.000 | 656.000 | 656.000 | 656.000 |
| Total weight [Kg] | 740 | 740 | 740 | 740 |
| Pit weight [Kg] | 250 | 250 | 250 | 250 |
| Bollard weight [Kg] | 490 | 490 | 490 | 490 |
| Operating temperature | -15 °C / +55 °C | -15 °C / +55 °C | ‐15 °C / +55 °C | ‐15 °C / +55 °C |
| Operating temperature with
heater (accessory) |
‐40 °C / +55 °C | ‐40 °C / +55 °C | ‐40 °C / +55 °C | ‐40 °C / +55 °C |
| Underground product dimensions
WxDxH [mm] |
570 x 690 x 1.665 | 570 x 690 x 1.665 | 570 x 690 x 1.665 | 570 x 690 x 1.665 |
| Required excavation dimensions
WxDxH [mm] |
3.200 x 1.600 x 1.800 | 3.200 x 1.600 x 1.800 | 3.200 x 1.600 x 1.800 | 3.200 x 1.600 x 1.800 |
| Supply cable | 16+1 conductors –
min. section 1,5mm (not supplied) |
16+1 conductors –
min. section 1,5mm (not supplied) |
16+1 conductors –
min. section 1,5mm (not supplied) |
16+1 conductors –
min. section 1,5mm (not supplied) |
| Max cable length [m] | 50 | 50 | 50 | 50 |